English
Language : 

REF01_05 Datasheet, PDF (4/12 Pages) Analog Devices – 10 V Precision Voltage Reference
REF01
@ VIN = 15 V, TA = 25°C, unless otherwise noted.
Table 3.
Parameter
Output Voltage
Output Adjustment Range
Output Voltage Noise1
S, Z, P Packages
J, 883 Parts
Line Regulation2
Load Regulation2
Turn-On Settling Time3
Quiescent Supply Current
Load Current
Sink Current4
Short-Circuit Current
Symbol
VO
∆VTRIM
e n p-p
e n p-p
tON
ISY
IL
IS
ISC
Conditions
IL = 0 mA
RP = 10 kΩ
0.1 Hz to 10 Hz
0.1 Hz to 10 Hz
VIN = 13 V to 33 V
IL = 0 mA to 8 mA
To ±0.1% of final value
No load
VO = 0
1 Sample tested.
2 Line and load regulation specifications include the effect of self-heating.
3 Guaranteed by design, not production tested.
4 During sink current test, the device meets the output voltage specified.
REF01C
Min
Typ
Max
9.90
10.00
10.10
±2.7 ±3.3
30
35
0.009
0.006
5
1.0
8
−0.3 −0.5
30
0.015
0.015
1.6
Unit
V
%
µV p-p
µV p-p
%/V
%/mA
µs
mA
mA
mA
mA
@ VIN = 15 V, 0°C ≤ TA ≤ +70°C for REF01CJ, REF01CZ, and −40°C ≤ TA ≤ +85°C for REF01CP and REF01CS, unless otherwise noted.
Table 4.
Parameter
Output Voltage Change
with Temperature1, 2
Output Voltage
Temperature Coefficient3
Change in VO Temperature
Coefficient with Output
Adjustment
Line Regulation4
Load Regulation4
Symbol
∆VOT
TCVO
Conditions
RP = 10 kΩ
VIN =13 V to 30 V
IL = 0 to 5 mV
REF01C
Min
Typ
Max
0.14
0.45
20
65
Unit
%
ppm/°C
0.7
0.011
0.008
0.018
0.018
ppm/°C
%/V
%/mA
1 ∆VOT is defined as the absolute difference between the maximum output voltage and the minimum output voltage over the specified temperature range expressed as
a percentage of 10 V:
∆VOT
= VMAX − VMIN
10 V
×100
2 ∆VOT specification applies trimmed to +10,000 V or untrimmed.
3 TCVO is defined as ∆Var divided by the temperature range; therefore,
TCVO (0°C
to + 70°C) =
∆VOT (0°C to +
70°C
70°C)
and
TCVO (− 55°C
to + 125°C) =
∆VOT (− 55°C to + 125°C)
180°C
4 Line and load regulation specifications include the effect of self-heating.
Rev. H | Page 4 of 12