OP420
ABSOLUTE MAXIMUM RATINGS1
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 18 V
Differential Input Voltage . . . . . . . . . . . . . . . . . . . . . . ± 30 V
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . Supply Voltage
Output Short-Circuit Duration . . . . . . . . . . . . . . Continuous
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (One Amplifier Only)
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Lead Temperature Range (Soldering, 60 sec) . . . . . . . 300°C
Operating Temperature Range
OP420CY, OP420CRC . . . . . . . . . . . . . . –55°C to +125°C
OP420G . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Junction Temperature (TJ) . . . . . . . . . . . . . –65°C to +150°C
Package Type
␪JA2
␪JC
Unit
14-Pin Hermetic DIP (Y) 99
14-Pin Plastic DIP (P)
76
16-Pin SOL (S)
92
12
°C/W
33
°C/W
27
°C/W
NOTES
1Absolute Maximum Ratings apply to packaged parts, unless otherwise noted.
2␪JA is specified for worst-case mounting conditions, i.e., ␪JA is specified for
device in socket for CerDIP and P-DIP packages; ␪JA is specified for device
soldered to printed circuit board for SOL package.
TA = 25°C VOS Max (mV)
4.0
4.0
4.0
Cer DIP 14-Pin
OP420CY*
*Not for new design; obsolete April 2002.
ORDERING GUIDE
Package Options
LCC 20-Contact
Plastic
OP420CRC/883
OP420GP*
OP420GS*
Operating Temperature Range
MIL
XIND
XIND
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the OP420 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. A