AD97651 Datasheet, PDF (4/28 Pages) Analog Devices – 12-Bit, 125 MSPS Dual TxDAC+ D/A Converter | |||
|
◁ |
AD9765âSPECIFICATIONS
DIGITAL SPECIFICATIONS (TMIN to TMAX, AVDD = +5 V, DVDD = +5 V, IOUTFS = 20 mA, unless otherwise noted.)
Parameter
Min
Typ
Max
DIGITAL INPUTS
Logic â1â Voltage @ DVDD = +5 V
Logic â1â @ DVDD = 3
Logic â0â Voltage @ DVDD = +5 V
Logic â0â @ DVDD = 3
Logic â1â Current
Logic â0â Current
Input Capacitance
Input Setup Time (tS)
Input Hold Time (tH)
Latch Pulsewidth (tLPW, tCPW)
3.5
5
2.1
3
0
1.3
0
0.9
â10
+10
â10
+10
5
2.0
1.5
3.5
Specifications subject to change without notice.
Units
V
V
V
V
µA
µA
pF
ns
ns
ns
ABSOLUTE MAXIMUM RATINGS*
Parameter
With
Respect to
Min
Max
Units
AVDD
DVDD
ACOM
AVDD
MODE, CLK1, CLK2, WRT1, WRT2
Digital Inputs
IOUTA1/IOUTA2, IOUTB1/IOUTB2
REFIO, FSADJ1, FSADJ2
GAINCTRL, SLEEP
Junction Temperature
Storage Temperature
Lead Temperature (10 sec)
ACOM
DCOM
DCOM
DVDD
DCOM
DCOM
ACOM
ACOM
ACOM
â0.3
+6.5
V
â0.3
+6.5
V
â0.3
+0.3
V
â6.5
+6.5
V
â0.3
DVDD + 0.3
V
â0.3
DVDD + 0.3
V
â1.0
AVDD + 0.3
V
â0.3
AVDD + 0.3
V
â0.3
AVDD + 0.3
V
+150
°C
â65
+150
°C
+300
°C
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum ratings
for extended periods may affect device reliability.
ORDERING GUIDE
Model
Temperature
Range
AD9765AST â40°C to +85°C
AD9765-EB
*ST = Thin Plastic Quad Flatpack.
Package
Description
Package
Option*
48-Lead LQFP ST-48
Evaluation Board
THERMAL CHARACTERISTICS
Thermal Resistance
48-Lead LQFP
θJA = 91°C/W
DATA IN
tS
tH
(WRT2) (WRT1 / IQWRT)
t LPW
(CLK2) (CLK1/ IQCLK)
IOUTA
OR
IOUTB
t CPW
t PD
Figure 1. Timing Diagram for Dual and Interleaved
Modes
See Dynamic and Digital sections for timing specifications.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD9765 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
â4â