English
Language : 

ADSP-216X Datasheet, PDF (30/39 Pages) Analog Devices – DSP Microcomputers with ROM
ADSP-216x
TIMING PARAMETERS (ADSP-2162/ADSP-2164/ADSP-2166)
INTERRUPTS AND FLAGS
Parameter
10.24 MHz
Min Max
13.0 MHz
Min Max
16.67 MHz
Min
Max
Frequency
Dependency
Min
Max
Unit
Timing Requirements:
tIFS IRQx1 or FI Setup Before
CLKOUT Low2, 3
44.4
tIFH IRQx1 or FI Hold After
CLKOUT High2, 3
24.4
Switching Characteristics:
tFOH FO Hold After CLKOUT High 0
tFOD FO Delay from CLKOUT High
15
39.2
19.2
0
15
35.0
0.25tCK + 20
ns
15.0
0.25tCK
ns
0
0
15
ns
15 ns
NOTES
1IRQx = IRQ0, IRQ1, and IRQ2.
2If IRQx and FI inputs meet tIFS and tIFH setup/hold requirements, they will be recognized during the current clock cycle; otherwise they will be recognized during the
following cycle. (Refer to the “Interrupt Controller” section in Chapter 3, Program Control, of the ADSP-2100 Family User’s Manual, Third Edition, for further
information on interrupt servicing.)
3Edge-sensitive interrupts require pulse widths greater than 10 ns. Level-sensitive interrupts must be held low until serviced.
CLKOUT
FLAG
OUTPUT(S)
IRQx
FI
tFOD
tFOH
tIFH
tIFS
Figure 28. Interrupts and Flags
–30–
REV. 0