English
Language : 

ADSP-21MSP5859 Datasheet, PDF (26/40 Pages) Analog Devices – DSP Microcomputers
ADSP-21msp58/59
Parameter
Min
Max
Unit
Interrupts and Flags
Timing Requirement:
tIFS
IRQx or FI Setup before CLKOUT Low1, 2, 3
0.25tCK + 15
ns
tIFH
IRQx or FI Hold after CLKOUT High1, 2, 3
0.25tCK
ns
Switching Characteristics:
tFOH
Flag Output Hold after CLKOUT Low4
tFOD
Flag Output Delay from CLKOUT Low4
0.5tCK – 7
ns
0.5tCK + 5 ns
NOTES
1If IRQx and FI inputs meet tIFS and tIFH setup/hold requirements, they will be recognized during the current clock cycle; otherwise the signals will be recognized on
the following cycle. (Refer to “Interrupt Controller Operation” in the Program Control chapter of the User’s Manual for further information on interrupt servicing.)
2Edge-sensitive interrupts require pulse widths greater than 10 ns; level-sensitive interrupts must be held low until serviced.
3IRQx = IRQ0, IRQ1, and IRQ2.
4Flag Output = FL0 and FO.
CLKOUT
FLAG
OUTPUTS
IRQ
FI
x
t F OD
t F OH
tI FH
tI FS
Figure 16. Interrupts and Flags
–26–