English
Language : 

ADSP-2166_15 Datasheet, PDF (23/39 Pages) Analog Devices – DSP Microcomputers with ROM
ADSP-216x
TIMING PARAMETERS (ADSP-2161/ADSP-2163/ADSP-2165)
INTERRUPTS AND FLAGS
Parameter
16.67 MHz
Min Max
20 MHz
Min Max
25 MHz
Min Max
Frequency Dependency
Min
Max
Unit
Timing Requirements:
tIFS IRQx1 or FI Setup Before
30
27.5
25
0.25tCK + 15
ns
CLKOUT Low2, 3
tIFS IRQx1 or FI Setup Before
33
30.5
28
0.25tCK + 18
ns
CLKOUT Low2, 3
tIFH IRQx1 or FI Hold After CLKOUT 15
12.5
10
0.25tCK
ns
High2, 3
Switching Characteristics:
tFOH FO Hold After CLKOUT High
0
tFOD FO Delay from CLKOUT High
15
0
0
0
15
124
ns
154
ns
NOTES
1IRQx = IRQ0, IRQ1, and IRQ2.
2If IRQx and FI inputs meet tIFS and tIFH setup/hold requirements, they will be recognized during the current clock cycle; otherwise they will be recognized during the
following cycle. (Refer to the “Interrupt Controller” section in Chapter 3, Program Control, of the ADSP-2100 Family User’s Manual, Third Edition for further
information on interrupt servicing.)
3Edge-sensitive interrupts require pulsewidths greater than 10 ns. Level-sensitive interrupts must be held low until serviced.
4For 25 MHz only, the maximum frequency dependency for tFOD = 12 ns.
CLKOUT
FLAG
OUTPUT(S)
IRQx
FI
tFOD
tFOH
tIFH
tIFS
Figure 22. Interrupts and Flags