English
Language : 

AD9942 Datasheet, PDF (18/36 Pages) Analog Devices – Dual-Channel, 14-Bit CCD Signal Processor with Precision Timing™ Core
AD9942
Table 14. CHN_A and CHN_B H1 to H4, RG, SHP, SHD Register Map
Address Data Bit Content Default (Hex) Name
Description
60
[12:0]
01001
H1CONTROL
H1 signal control. Polarity [0] (0 = inversion; 1 = no inversion).
H1 positive edge location [6:1].
H1 negative edge location [12:7].
61
[12:0]
00801
RGCONTROL
RG signal control. Polarity [0] (0 = inversion; 1 = no inversion).
RG positive-edge location [6:1].
RG negative-edge location [12:7].
62
[14:0]
0
DRVCONTROL
Drive-strength control for H1X [2:0], H2X [5:3], H3X [8:6], H4X [11:9],
and RG_X [14:12].
Drive-current values: 0 = off, 1 = 4.3 mA, 2 = 8.6 mA, 3 = 12.9 mA,
4 = 17.2 mA, 5 = 21.5 mA, 6 = 25.8 mA, 7 = 30.1 mA.
63
[11:0]
00024
SAMPCONTROL SHP/SHD sample control. SHP sampling location [5:0]. SHD sampling
location [11:6].
64
[5:0]
0
DOUTPHASE DOUT phase control.
Table 15. CHN_A and CHN_B AFE Operation Register Detail
Address Data Bit Content Default (Hex) Name
00
[1:0]
0
PWRDOWN
[2]
1
CLPENABLE
[3]
0
CLPSPEED
[4]
0
FASTUPDATE
[5]
0
PBLK_LVL
[7:6]
0
TEST MODE
[8]
0
DCBYP
[9]
0
TESTMODE
[11:10]
0
TESTMODE
Description
0 = normal operation; 1 = reference standby; 2/3 = total power-down.
0 = disable CLPOB; 1 = enable CLPOB.
0 = select normal CLPOB settling; 1 = select fast CLPOB settling.
0 = ignore VGA update; 1 = very fast clamping when VGA is updated.
DOUT value during PBLK; 0 = blank to zero; 1 = blank to clamp level.
Internal test mode. Should always be set = 3.
0 = enable dc restore circuit; 1 = bypass dc restore circuit during PBLK.
Test operation only. Set = 0.
Test operation only. Set = 0.
Table 16. CHN_A and CHN_B AFE Control Register Detail
Address Data Bit Content Default (Hex) Name
03
[1:0]
0
TESTMODE
[2]
1
TESTMODE
[3]
0
DOUTDISABLE
[4]
0
DOUTLATCH
[5]
0
GRAYENCODE
Description
Test operation only. Set = 0.
Test operation only. Set = 0.
0 = data outputs are driven; 1 = data outputs are three-stated.
0 = latch data outputs with DOUT phase; 1 = output latch transparent.
0 = binary encode data outputs; 1 = gray encode data outputs.
Rev. A | Page 18 of 36