ADSP-2183 Datasheet, PDF (16/31 Pages) Analog Devices – DSP Microcomputer | |||
|
◁ |
ADSP-2183
Parameter
Memory Read
Timing Requirements:
tRDD
RD Low to Data Valid
tAA
A0âA13, xMS to Data Valid
tRDH
Data Hold from RD High
Switching Characteristics:
tRP
RD Pulsewidth
tCRD
CLKOUT High to RD Low
tASR
A0âA13, xMS Setup before RD Low
tRDA
A0âA13, xMS Hold after RD Deasserted
tRWR
RD High to RD or WR Low
w = wait states à tCK.
xMS = PMS, DMS, CMS, IOMS, BMS.
Min
0
0.5tCK â 5 + w
0.25tCK â 2
0.25tCK â 4
0.25tCK â 3
0.5tCK â 5
Max
Unit
0.5tCK â 8 + w
ns
0.75tCK â 10.5 + w ns
ns
ns
0.25tCK + 7
ns
ns
ns
ns
CLKOUT
A0 â A13
DMS, PMS,
BMS, IOMS,
CMS
RD
D
WR
tASR
tCRD
tRP
tRDD
tAA
tRDA
tRWR
tRDH
Figure 11. Memory Read
â16â
REV. C
|
▷ |