English
Language : 

ADP2291_15 Datasheet, PDF (11/20 Pages) Analog Devices – Compact, 1.5 A Linear Charger for Single-Cell Li Battery
THERMAL SHUTDOWN
If the ADP2291 junction temperature rises above 135°C,
thermal shutdown occurs. Extreme junction temperatures can
be the result of excessive current operation and/or high ambient
temperatures.
ADP2291
A 35°C temperature hysteresis is included so that the ADP2291
does not return to operation during thermal shutdown until the
on-chip temperature drops below 100°C.
ADJ
IN
CS
DRV
BAT
3V
GM
5V
GM
GM
1.2V
VOLTAGE
REFERENCE
0.4V
IN
BAT
IN
3.8V
IPNP
C/10
TEMP
SHUTDOWN
RESTART
VIN_GOOD
POWER_DOWN
CONTROL
LOGIC
PRECHARGE
END_OF_CHARGE
TIMER
TIMER
Figure 20. Functional Block Diagram
BAT
4.1V
BAT
2.5V
CHG
Rev. A | Page 11 of 20