English
Language : 

ADUM1310_07 Datasheet, PDF (10/20 Pages) Analog Devices – Triple-Channel Digital Isolators
ADuM1310/ADuM1311
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
IC Junction-to-Case Thermal Resistance
Side 1
Side 2
Symbol
RI-O
CI-O
CI
θJCI
θJCO
Min Typ
1012
2.2
4.0
33
28
Max Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at center of
package underside
1 Device considered a 2-terminal device; Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15, and
Pin 16 shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM131x have been approved by the organizations listed in Table 5.
Table 5.
UL 1
Recognized under 1577 component
recognition program
Single/basic insulation,
2500 V rms isolation voltage
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-
03 and IEC 60950-1,
400 V rms maximum working voltage
File E214100
File 205078
VDE 2
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-01
Basic insulation, 560 V peak
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950: 2000
Reinforced insulation, 560 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM131x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
2 In accordance with DIN EN 60747-5-2, each ADuM131x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN EN 60747-5-2 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
2500
7.7 min
8.1 min
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. F | Page 10 of 20