6. ABSOLUTE MAXIMUM RATINGS
Table 3. Absolute Maximum Ratings
(Do not exceed these limits to prevent damage to the device. Exposure to absolute maximum rating conditions for long periods may affect device
reliability.)
PARAMETER
VALUE
UNIT
VHM, DRM to VSSP
-0.3 to 54
V
VP to VSS
-0.3 to 17
V
CSM, REGO to VSS
-0.3 to VP + 0.3
V
VSYS, AIO6/.. to VSS
-0.3 to 6
V
VCC33 to VSS
-0.3 to 4.1
V
VCC18 to VSS
-0.3 to 2.5
V
AIOx/.. (except AIO6/..), VCCIO, CLKOUT/ENHS2 to VSS
PDx/.., PEx/.. to VSS
XIN, XOUT to VSS
PCx/.. to VSSA
DRLx to VSSP
DXBx to VSSP
-0.3 to VSYS + 0.3
V
-0.3 to VCCIO + 0.3
V
-0.3 to VCC18 + 0.3
V
-0.3 to VCC33 + 0.3
V
-0.3 to VP + 0.3
V
-0.3 to 630
V
DXSx to VSSP
-11 to 610
V
DXSx allowable offset slew rate (dVDXSx/dt)
-50 to 50
V/ns
DXBx, DXHx to respective DXSx
-0.3 to 22
V
OMx to VSSP
-0.3 to 24
V
VSSP, VSSA to VSS
-0.3 to 0.3
V
VSS, VSYS, DRM, DRLx, DXHx, REGO, OMx RMS current(1)
VSSP RMS current(1)
VP RMS current(1)
Operating temperature range
0.2
0.4
0.6
-40 to 105
ARMS
ARMS
ARMS
°C
Human body model (JEDEC)
2
kV
Electrostatic discharge (ESD)
Charge device model (JEDEC)
800
V
Machine model (JEDEC)
(1) Peak current can be 10 times higher than RMS value for pulses shorter than 10µs.
200
V
- 11 -
Rev 1.6‒January 28, 2016