6. ABSOLUTE MAXIMUM RATINGS
Table 6-1. Absolute Maximum Ratings
(Do not exceed these limits to prevent damage to the device. Exposure to absolute maximum rating conditions for long periods may affect
device reliability.)
PARAMETER
VALUE
UNIT
VHM, DRM to VSSP
-0.3 to 54
V
VP to VSS
-0.3 to 17
V
CSM, REGO to VSS
-0.3 to VP + 0.3
V
VSYS, VCCIO, AIO6/.. to VSS
-0.3 to 6
V
VCC33 to VSS
-0.3 to 4.1
V
VCC18 to VSS
-0.3 to 2.5
V
AIOx/.. (except AIO6/..), ENHS1, ENHS2 to VSS
-0.3 to VSYS + 0.3
V
PAx/.., PDx/.., PEx/.. to VSS
-0.3 to VCCIO + 0.3
V
XIN, XOUT to VSS
-0.3 to VCC18 + 0.3
V
PCx/.. to VSSA
-0.3 to VCC33 + 0.3
V
OMx to VSSP
-0.3 to 24
V
VSSP, VSSA to VSS
-0.3 to 0.3
V
VSS, VSYS, DRM, REGO, OMx RMS current(1)
0.2
ARMS
VSSP RMS current(1)
0.4
ARMS
VP RMS current(1)
0.6
ARMS
Operating temperature range
-40 to 105
°C
Human body model (JEDEC)
2
kV
Electrostatic discharge (ESD)
Charge device model (JEDEC)
1
kV
Machine model (JEDEC)
200
V
(1) Peak current can be 10 times higher than RMS value for pulses shorter than 10µs.
- 11 -
Rev 1.0‒February 28, 2014