English
Language : 

ACTF45-48 Datasheet, PDF (1/6 Pages) Advanced Crystal Technology – the characteristics of the SAW Duplexer
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: info@actcrystals.com
1. Scope
This specification covers the characteristics of the SAW Duplexer
ACTF45-48/44.25-48.24/W2 used for cordless telephones.
2. Package
3. Characteristics
Standard atmospheric conditions
Unless otherwise specified, the standard range of atmospheric conditions for making
measurements and tests is as follows:
Ambient temperature: 15°C to 35°C
Relative humidity:
25% to 85%
Air pressure:
86kPa to 106kPa
Operating temperature range
Operating temperature range is the range of ambient temperatures in which the
filter can be operated continuously. -10°C ~ +50°C
Storage temperature rang
Storage temperature range is the range of ambient temperatures in which the filter
can be stored without damage.
Conditions are as specified elsewhere in these specifications. -40°C ~ +70°C
Reference temperature
3.1 Maximum Rating
DC voltage
Source power
+25°C
VDC
Ps
0
V
15
dBm
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04