05/05/10
MAXIMUM RATINGS*
Symbol
Parameter
Value
Vin
Supply Voltage (Referenced to Ground)
Vip
Voltage applied to any Input Pin (Referenced to Ground)
Iop
Current sourced or sinked from any Output Pin
Pin
Input Power (DC Input Voltage x DC Input Current)
Top
Operating Temperature (Still air ambient around Inverter)
Tstg
Storage Temperature
-0.7 to 14
-0.7 to 5.7
+/- 10
43.5
-20 to +70
-40 to +105
*Maximum Ratings are those values beyond which damage to the inverter may occur
Unit
Vdc
Vdc
mAdc
W
°C
°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Vin
Lsv
Vcntl
Parameter
Supply Voltage (Referenced to Ground)
Cold Cathode Fluorescent Lamp Sustaining Voltage
Intensity Control Voltage
Min Max
10.8 13.2
747
913
0
5.0
Unit
Vdc
Vrms
Vdc
ELECTRICAL CHARACTERISTICS
Vin = +12.0V, Lsv = 830Vrms, Vcntl = +5.0V, Enable = +5V unless otherwise specified
Symbol
Parameter
Test Conditions
Min
Lstart Lamp Starting Voltage
Open Circuit
1730
Lout
Lamp Output Current
5.85
Lfreq Lamp-Current Frequency
27.9
Pfreq PWM Dimming Frequency
Vcntl (Pin 7)= +2.5V
95
Pdc
PWM Duty Cycle Range
Vcntl (Pin 7)= 0 to +5.0V
0
ENoff Enable Control, unit OFF (Pin 5)
ENon Enable Control, unit ON (PIN 5)
2.0
+5Vout +5V Reference Out (Pin 6)
10k load to ground
4.75
Iin
Input Current Draw
Eff
Electrical Efficiency
90
Max
7.15
34.1
101
100
0.8
5.25
3.3
Unit
Vrms
mArms
KHz
Hz
%
Vdc
Vdc
Vdc
Adc
%