English
Language : 

ASTMK06 Datasheet, PDF (1/5 Pages) Abracon Corporation – RTC reference clock
Ultra-miniature, Low Power, 32.768kHz SMD MEMS Oscillator
ASTMK06
ESD Sensitive
Moisture Sensitivity Level (MSL) – 1
FEATURES:
• Ultra-miniature size: 2.0 x 1.2 x 0.6mm
• Supply Voltage: 1.5V to 3.63V
• Ultra-Low Current Consumption: 1.0µA typ.(no load)
• Frequency Stabilities include:
±75ppm over -10 to +70°C
±100ppm over -40 to +85°C
• Internal power supply filtering eliminates external bypass
capacitor for Vdd port.
• High Performance MEMS Technology by SiTime
Pb RoHS/RoHS II compliant
APPLICATIONS:
• General Timekeeping
• Battery Management
• Portable devices
• RTC reference clock
• Bluetooth/WiFi modules
2.0 x 1.2 x 0.6mm
STANDARD SPECIFICATIONS:
Parameters
Min
Typ
Max Unit
Notes
Output Frequency (Fout)
Initial Frequency Tolerance (Finit) (1)
-20
Frequency Stability over Temperature
-75
(Fstab) (2)
-100
Aging (@+25°C)
-1
32.768
+20
+75
+100
+1
kHz
ppm
ppm
ppm
TA= +25°C, post reflow,
Vdd:1.5-3.63V
TA= -10°C to +70°C, Vdd:1.5-3.63V
TA= -40°C to +85°C, Vdd:1.5-3.63V
First year
Supply Voltage (Vdd)
1.5
3.63
1.0
Current Consumption ( Idd )
1.9
2.2
Power Supply Ramp (tVdd_Ramp)
100
180
300
Start-up Time at Power-up (Tstart)
450
500
Operating Temperature Range (Tuse)
-10
-40
+70
+85
LVCMOS Output (TA= Over Temperature. Typical values are at TA= +25°C)
Output Rise/Fall Time (tr/tf)
100
200
Output Clock Duty Cycle
48
52
V TA= over temperature
TA= +25°C, Vdd:1.5-3.63V.
No load.
µA
TA= -10°C to +70°C,
Vdd max: 3.63V. No load
TA= -40°C to +85°C,
Vdd max: 3.63V. No load.
ms Over temperature, 0 to 90% Vdd
TA= +25°C±10°C
ms TA= -40°C to +70°C
TA= +85°C
°C
Option “M”
Option “L”
ns 10-90%, 15pF load, Vdd:1.5-3.63V
%
Output Voltage
VOH
VOL
Output Drive Level
90%*Vdd
10%*Vdd
50
V
Vdd:1.5-3.63V. IOH= -10µA, 15pF
Vdd:1.5-3.63V. IOL= 10µA, 15pF
pF
≥80% LVCMOS swing, Vdd:1.8V,
2.5V, 3.3V
Period Jitter (Tjitt)
35
nsRMS Cycles – 10000, TA= +25°C
Note:
1. Measured peak-to-peak. Tested with Agilent 53132A frequency counter. Due to the low operating frequency, the gate time
must be ≥100ms to ensure an accurate frequency measurement.
2. Measured peak-to-peak. Inclusive of initial tolerance at +25°C, and variations over operating temperature, rated power
supply voltage and load.
ABRACON IS
ISO9001:2008
CE RTIFIED
5101 Hidden Creek Lane Spicewood TX 78669 Revised: 06.17.2017
Phone: 512-371-6159 | Fax: 512-351-8858
LLC For terms and conditions of sales please visit:
www.abracon.com