English
Language : 

AB-RTCMC-32.7KHZ-AIGZ-S7 Datasheet, PDF (1/7 Pages) Abracon Corporation – Real Time Clock Module with I2C Bus
Real Time Clock Module with I2C Bus
AB-RTCMC-32.768kHz-AIGZ-S7
Moisture Sensitivity Level: MSL=1
Pb RoHS/RoHS II compliant
3.2 x 1.5 x 0.8 mm
FEATURES:
• With state-of-the-art RTC Technology by Micro Crystal AG
• RTC module with built-in crystal oscillating at 32.768 kHz
• 350 nA timekeeping current at 3 V
• Timekeeping down to 1.0 V
• 1.3 V to 4.4 V I2C bus operating voltage
• Low operating current of 35 μA (at 400 kHz)
• 32.768kHz square wave on power-up to drive a microcontroller in
low-power mode– Programmable from 1 Hz to 32.768kHz;– Can be disabled
• 400 kHz I2C serial interface
• Oscillator stop detection circuit monitors clock operation
• Accurate programmable watchdog– 62.5 ms to 31 min timeout
• Counters for tenths/hundredths of seconds, seconds, minutes, hours, day, date,
month, year, and century
• Software clock calibration to compensate deviation of crystal due to temperature
• Automatic leap year compensation
• Ultra-small, 3.2 x1.5 mm, lead-free 8-pin ceramic leadless chip carrier
APPLICATIONS:
• Wide range in communication & measuring equipment
• Commercial & Industrial applications
• Automotive electronics applications
• Wireless communications
• PDA and Palm Pilots
• Credit Cards with Security Technology
STANDARD SPECIFICATIONS:
Absolute Maximum Ratings
In accordance with the Absolute Maximum Rating System IEC 60134
Parameters
Supply Voltage
Input Voltage
Output Voltage
Output Current
Power Dissipation
Operating Ambient Temperature
Range
Storage Temperature Range
Electro Static Discharge Voltage
Symbol
VDD
VI
VO
IO
PD
TOPR
TSTO
VESD
Conditions
>GND / <VDD
Stored as bare
product
HBM1) TA = 25°C
MM2) TA = 25°C
Min.
GND-0.3
GND-0.2
GND-0.2
-40
Max.
+5.0
VDD+0.3
VDD+0.3
20
1
+85
-55
+125
>1500
>1000
Units
V
V
V
mA
W
°C
°C
V
1) HBM: Human Body Model, according to JESD22-A114.
2) MM: Machine Model, according to JESD22-A115.
These data are based on characterization results, not tested in production. Stresses above these listed maximum ratings may cause
permanent damage to the device. Exposure beyond specified operating conditions may affect device reliability or cause malfunction.
Operating and AC Measurement Conditions 1)
Parameters
Symbol
Min.
Max.
Units
Supply Voltage
VDD
1.3
Operating Ambient Temperature
TA
-40
Load Capacitance
CL
Input Rise and Fall Times
4.4
V
+85
°C
50
pF
5
ns
Input Pulse Voltages
Input and Output timing ref.
Voltage
0.2*VDD
0.3*VDD
0.8*VDD
V
0.7*VDD
V
1) Output Hi-Z is defined as the point where data is no longer driven.
ABRACON IS
ISOIS9O090010/1Q:S2090800
CERTIFIED
Visit www.abracon.com for Terms & Conditions of Sale Revised: 01.08.14
30332Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com