SPECIFICATION FOR APPROVAL
REF :
PAGE: 5
PROD.
NAME
WOUND CHIP INDUCTOR
RELIABILITY TEST
ABC'S DWG NO.
ABC'S ITEM NO.
CC2520□□□□3□-□□□
Test item
Specification
Electrical performance test
Inductance L
Q
Self resonance
frequency SRF
DC Resistance RDC
Refer to standard
electrical
characteristic list
Rated current IDC
Temperature
rise test
20 max.
Over load test
Withstanding
voltage test
Insulation
resistance test
After test Inductors
shall be no evidence
of electrical and
mechanical damage
After tset Inductors
shall be no evidence
of electrical and
mechanical damage
1000 MΩ min
Mechanical performance test
Vibration test
( Low frequency )
1 Inductors shall be
no evidence of
electrical and
mechanical damage
Test condition / Test method
□HP4194A with HP-16034E test fixture
□HP4291A with HP-16093A test fixture
CH-502AC
Applied the current to coils The
Inductance change shall be less than 10%
to initial value & temperature rise shall
not be more than 20
1 Applied the allowed DC current for
10 minutes
2 Temperature measure by digital
surface thermometer
Applied 2 times of rated allowed DC
current to inductor for a period of
5 minutes
AC voltage of 1000VAC applied between
inductors terminal and coating for 5 seconds
100 VDC applied between inductor terminal and coating
1 Amplitude 1.5 m/m
2 Frequency 10 -- 55 -- 10 Hz / 1min.
3 Direction X Y Z
4 Duration 2 hrs / X Y Z
Shock test
2 Inductance shall
not change more
than±5%
Inductors shall be dropped 10 times from
a height of 1m onto 3cm wooden board
Resistance to
soldering heat
3 Q Shall not change
more than ±20%
Temp 260±5
Time 10±1.0 sec.