Ai329CA
BIAS CONDITION
Parameter
Output amplifier drain voltage
Substrate voltage adjustment range
Fluctuation range after substrate voltage adjustment
Reset gate clock voltage adjustment range
Fluctuation range after reset gate voltage adjustment
Protection bias
Symbol
VDD
VSUB
¦VSUB
VRG
¦VRG
VP
Min Typ Max Unit
14.5 15.0 15.5
V
5
15
V
–1
1
V
0
4
V
–3
3
%
Set to low level
of vertical transfer clock
Remark
*
* No adjustment of reset gate clock voltage is necessary when reset gate clock is driven as indicated below.
Parameter
Reset gate clock voltage
Symbol
VRGL
VRG
Min Typ Max Unit
–0.2
0.0
0.2
V
8.5
9.0
9.5
V
Remarks
DC CHARACTERISTICS
Parameter
Output amplifier drain current
Symbol
IDD
Min Typ Max
Unit
–
3
–
ɶ
DRIVING CONDITION
Parameter
Vertical clock high voltage
Vertical clock middle voltage
Vertical clock low voltage
Horizontal clock high voltage
Horizontal clock low voltage
RG clock voltage difference
Substrate clock voltage
Symbol
VH1, VH3
VM1, 2, 3, 4
VL1, 2, 3, 4
HH1, 2
HL1, 2
RGHL
VSUB
Min
14.5
–0.2
–9.0
4.5
–0.5
4.7
23
Typ
15.0
0.0
–8.5
5.0
0.0
5.0
24
Max
15.5
0.2
–8.0
5.5
0.5
5.3
25
Unit
V
V
V
V
V
V
V
3