English
Language : 

AP20GT60ASP-HF_14 Datasheet, PDF (1/3 Pages) Advanced Power Electronics Corp. – High Speed Switching
Advanced Power
Electronics Corp.
AP20GT60ASP-HF
Halogen-Free Product
N-CHANNEL INSULATED GATE
BIPOLAR TRANSISTOR
Features
▼ High Speed Switching
▼ Low Saturation Voltage
VCE(sat),typ.=1.7V@IC=19A
▼ RoHS Compliant Product
G
C
E
TO-220(P)
VCES
IC
G
600V
19A
C
Absolute Maximum Ratings
Symbol
VCES
VGE
IC@TC=25oC
IC@TC=100oC
ICM
IF@TC=100oC
IFM
PD@TC=25oC
TSTG
TJ
Parameter
Collector-Emitter Voltage
Gate-Emitter Voltage
Collector Current
Collector Current
Pulsed Collector Current1
Diode Forward Current
Diode Pulse Forward Current
Maximum Power Dissipation
Storage Temperature Range
Operating Junction Temperature Range
Notes:
1.Pulse width limited by Max. junction temperature .
Rating
600
+20
33
19
72
8
40
78.1
-55 to 150
150
E
Units
V
V
A
A
A
A
A
W
oC
oC
Thermal Data
Symbol
Parameter
Rthj-c
Thermal Resistance Junction-Case
Rthj-c(Diode) Thermal Resistance Junction-Case
Rthj-a
Thermal Resistance Junction-Ambient
Value
1.6
2.4
62
Units
oC/W
oC/W
oC/W
Electrical Characteristics@Tj=25oC(unless otherwise specified)
Symbol
IGES
ICES
VCE(sat)
VCE(sat)
VGE(th)
Qg
Qge
Qgc
td(on)
tr
td(off)
tf
Eon
Eoff
Cies
Coes
Cres
Parameter
Gate-to-Emitter Leakage Current
Collector-Emitter Leakage Current
Collector-Emitter Saturation Voltage
Collector-Emitter Saturation Voltage
Gate Threshold Voltage
Total Gate Charge
Gate-Emitter Charge
Gate-Collector Charge
Turn-on Delay Time
Rise Time
Turn-off Delay Time
Fall Time
Turn-On Switching Loss
Turn-Off Switching Loss
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Test Conditions
VGE=+20V, VCE=0V
VCE=600V, VGE=0V
VGE=15V, IC=19A
VGE=15V, IC=25A
VCE=VGE, IC=250uA
IC=20A
VCC=480V
VGE=15V
VCE=480V,
Ic=20A,
VGE=15V,
RG=5Ω,
Inductive Load
VGE=0V
VCE=30V
f=1.0MHz
Min. Typ. Max. Units
-
- +100 nA
-
-
1 mA
- 1.7 2.2 V
- 1.9 -
V
2
-
6
V
- 95 150 nC
- 16 - nC
- 35 - nC
- 40 - ns
- 20 - ns
- 140 - ns
- 200 400 ns
- 0.1 - mJ
-
1
- mJ
- 2760 4400 pF
- 65 - pF
- 40 - pF
VF
FRD Forward Voltage
trr
FRD Reverse Recovery Time
Qrr
FRD Reverse Recovery Charge
IF=8A
IF=8A
di/dt = 100 A/μs
- 1.8 2.4 V
- 30 - ns
- 30 - nC
Data and specifications subject to change without notice
1
201112271