English
Language : 

AB-5000 Datasheet, PDF (1/2 Pages) 3M Electronics – EMI Absorber
AB-5000
EMI Absorber
Data Sheet
Product Description
3Μ™ AB-5000 Series EMI Absorber consists of
flexible soft metal flakes filler in polymer resin
with acrylic pressure-sensitive adhesive.
• Polymer resin and metal flakes filler
• Acrylic pressure-sensitive adhesive
• Supplied on a removable liner for easy
handling and die-cutting
The AB-5000 Series EMI Absorber is available in
standard A4 size and 210mm (width) X 15 meters
(length) in roll.
Applications
The AB-5000 Series EMI Absorber is typically
used for applications requiring electromagnetic-
absorbing performance. It suppresses radiated
noise from electrical devices for broadband radio
frequency range.
Common uses include mobile phone (SAR
reduction), computer, digital still camera, RF
block, military equipments for radar avoidance
and stealth performance.
Attenuation and Power Loss
Many factors determine the true attenuation of an
electromagnetic absorbing material, including
shape and thickness, intimacy of substrate contact,
smoothness of application surface, strength and
frequency of the EMI signal, etc. However, using
standard tests and fixtures, it is possible to
determine a value for the signal attenuation.
The typical attenuation range of the 3M AB-5000
Series EMI Absorber depends on thickness.
3M AB-5000 EMI Absorber – Typical Properties
Properties
Typical Value
Type of Backing
Polymer resin with metal flake filler
Type of Adhesive
Acrylic non-conductive pressure-sensitive adhesive (PSA)
Product Number
AB-5010
AB-5020
AB-5030
AB-5050
AB-5100
Thickness 1
0.10mm
0.20mm
0.30mm
0.50mm
1.00mm
Standard packaging
210mm x 297mm
Temperature range
-25 ~ 85℃
Surface resistivity 2
1x10 6Ω(min)
Thermal conductivity
0.7 W/mK
Tensile strength 3
6.0MPa(min)
Attenuation (S11 Reflection Refer to attenuation and power loss graphs
Loss) and Power Loss4
1. This value does not contain a double-side adhesive tape thickness. Typical adhesive tape thickness is 50 ㎛ (AB-5010 contains 30 ㎛ adhesive)
2. Test method : ASTM D257
3. Test method : JIS K 6251
4. Attenuation measured by 7mm coaxial verification kit under short fixed condition. Power loss measured by 50Ωmicrostrip line.